K. A. Group Holdings Pte Ltd
+65 6747 1747, +65 6747 2579
+65 9238 7257(MS.CAREN SOH)
General Enquiry:
info@ka.com.sg
Home
About Us
products & applications
Projects
News & Events
Contact Us
VERMICULITE
FIREPROOFING
SPRAY
products &
applications
1.
Fireproofing for Structural Steel
Vermiculite Fireproofing Spray
Intumescent Paint
2.
Fire Compartmentation
Insulated Fire Rated Fabric Shutters / Fire Curtain
Non Insulated Fire Rated Fabric Shutters / Fire Curtain
3.
Fireproofing For Mechanical Services
Dry/Wet Riser: Mortar-Based System & Fire-Rated Board
Ductwork: Fire-Rated Board
4.
Firestopping For Construction Joints & Openings
Sealant- Based Firestop System
Mortar- Based Firestop System
5.
Firestopping For Facade
Curtain Wall
Open ventilated facade
6.
Roof Insulation & Slabs Top-Up
Vermix® Lightweight Concrete
7.
Exfoliated Vermiculite
Vermiculite G2 / G4
Home
>
products & applications
>
Fireproofing for Structural Steel
>
Vermiculite Fireproofing Spray
Vermiculite Fireproofing Spray
Description
Vermiculite spray is a tough, hard and highly stable passive fire protection coating applied to structural steel members by spray application. It can be also applied by troweling, when necessary. It consists of factory produced blend of exfoliated vermiculite, cementitious binders and rheological and mix dispersing agents supplied as a dry mix to which clean water is added on site. It does not respond to any form of expansion, foaming or chemical reaction to impart its fire protection properties.
Available in 2 grades:
Internal Grade – robust, economic coating for internal use
External Grade – tough coating for external use, resistant to variety of climatic conditions
Application
Both grades are designed for installation by spray techniques. It can be applied to bare steel surfaces in the thickness of up to 30 mm at a time. The surface of the steel should be dry and free of dirt, oil, loose mill scale, flaking paint and loose rust.
Fire Performance
As applied, both grades of spray are rated “Non-combustible” to BS476 Part 4:1970 and comply with performance requirements of “Class O” as defined in Building Regulations.
Both grades have been fully tested on structural steel beams and columns for up to 4hours fire resistance in accordance with BS476 Part21: 1987.
The Thickness of the fire protection material required for a given period of fire resistant is dependent upon the surface area of the steel member exposed to fire and its equivalent cross sectional area (Hp/A) value for the section. Detailed information on the required thickness for SLV is available upon request.